User Tools

Site Tools


software:imaged11

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
software:imaged11 [2019/05/28 09:59]
matthias
software:imaged11 [2019/11/28 13:35] (current)
smerkel
Line 67: Line 67:
 {{ software:​imaged11_parameters.png?​300|Screenshot of the parameter window}} {{ software:​imaged11_parameters.png?​300|Screenshot of the parameter window}}
 After you loaded a file you should modify the parameters. For this, click on ''​Transformation''​ and ''​Edit parameters''​. You will see a window like the one to the right. Enter all necessary parameters. Necessary are usually these ones: After you loaded a file you should modify the parameters. For this, click on ''​Transformation''​ and ''​Edit parameters''​. You will see a window like the one to the right. Enter all necessary parameters. Necessary are usually these ones:
-  * Cell parameters: cell_a, cell_b, cell_c in Angstrom; cell_alpha, cell_beta, cell_gamma in degrees +  ​* **Cell parameters**: cell_a, cell_b, cell_c in Angstrom; cell_alpha, cell_beta, cell_gamma in degrees ​(typically taken from [[software:​maud|Maud]] refinement) 
-  * Lattice type: P = primitive, F = face-centered,​ A = A-centered, ... +  ​* **Lattice type**: P = primitive, F = face-centered,​ A = A-centered, ... 
-  * Distance = sample-detector distance in µm +  ​* **Distance** = sample-detector distance in µm (typically taken from [[software:​maud|Maud]] refinement) 
-  * O-matrix (check the [[|concept of the O-matrix]] if you are not sure) +  ​* **O-matrix** (check the [[dac_experiments:​geometry|concept of the O-matrix]] if you are not sure) 
-  * Omegasign = rotation direction (1 = clockwise, -1 = counterclockwise) +  ​* **Omegasign** = rotation direction (1 = clockwise, -1 = counterclockwise) 
-  * Tilt (be careful with this one: Tilt in ImageD11 is sometimes not the same as tilt in other software!) +  ​* **Tilt**: Be careful with this one: Tilt in ImageD11 is sometimes not the same as tilt in other software! ​(usually keep 0 and refine later
-  * Wavelength in Angstrom +  ​* **Wavelength** in Angstrom 
-  * y_size, z_size: size of one pixel in y direction and z direction in µm +  ​* **y_size****z_size**: size of one pixel in y direction and z direction in µm 
-  * y_center, z_center: pixel coordinates of the beam center (if your detector ​has 2048x2048 pixels ​the center ​is usually somewhere close to 1024x1024)+  ​* **y_center****z_center**: pixel coordinates of the beam center (usually taken from [[software:​dioptas|Dioptas calibration]]:​ ''​y_center = Dioptas Center X''​ and ''​z_center = 2048 - Dioptas Center Y''​) 
 +  * Supplementary parameter **cell_sg**. You can also provide ​your material space group. This has to be done manually with a text editor and can not be done using the Graphical User Interface. If the space group is provided, ImageD11 will use xfab for generate unique hkls.
  
 === Typical mistakes during parameter entering === === Typical mistakes during parameter entering ===
software/imaged11.1559037562.txt.gz · Last modified: 2019/05/28 09:59 by matthias